Shell-and-tube condensers for pure vapours (KOND)

KOND module package

Try

Buy

Design of shell-and-tube condensers for pure vapours

Basis

The theory is based on the correlations found in the VDI Heat Atlas, the HEDH (Heat Exchanger Design Handbook), and various research papers.

Program features:

The KOND program is based on the WTS program and needs that program for the calculation. Therefore, the operation of KOND is almost identical.

The KOND program serves for the calculation of shell-and-tube condensers with desuperheating, condensation and subcooling zones. No subcooling of the condensate is calculated for horizontal condensers with shell-side condensation. The condensation can either take place around the tubes or in the tubes but is restricted pure vapours (no mixtures).

KOND can only calculate condensers with one tube side pass.

Specific program features:

Scope of delivery:

Module package WTS and KOND as extension.

With the SPIE module in the KOND program the following features are available:

Price for KOND as an extension of WTS: 600 EUR plus VAT

(latest version of WTS required)

  Module Standard
Version
Extra
Charge
Construction types
Shell and tube condenser with desuperheating, condensation and subcooling KOND X
Countercurrent flow   X  
Bare tubes internal/external   X  
with segmental baffles   X  
Straight tube   X  
No tubes in window   X  
TEMA Standard TEMA X  
Steady-state temperature distribution ZELL X
Tube vibration analysis RBSA X  
Shell without baffles GGO   X
Corrugated tubes DRLL   X
Physical properties
Water and steam H2O X  
Sea water SAWA X  
Saturated steam condensation H2O X  
Natural gas H, L and any composition EGAS X  
Flue gas RGAS X  
Ammonia and ammoniacondensation NH3 X  
12 typical machine oils OEL X  
100 thermal oils TOIL X  
Air (dry) LUFT X  
® Antifrogens N, L, KF and SOL GLYC X  
Free input of properties SDAT X  
Refrigerants FRIG X  
Heavy fuel oils HFO X
Sulfuric acid H2SO   X
Nitric acid HNO3   X
Hydrochloric acid HCL X
Sodium hydroxide NAOH X
Nitrogen N2 X
Carbon dioxide / CO2 condensation CO2   X
Helium He   X
N2 O2 H2 CO CO2 H2O SO2 SO3 - mixtures of any composition Gas mixture   X
Aqueous sucrose solutions SAC   X
Properties of pure substances and mixtures
(requires program PROPER)
PROP   X
User-supplied properties tables STAB   X
Miscellaneous 
Interface to strength calculation
True-to-scale sketch of heat exchangers including essential dimensioning
WTSC X  
Tube sheet library
Creating a design-specific tube sheet.
Tube sheet that can be edited as DXF file
SPIE X  
Customer documentation (abridged) KUDO X  
Specification sheet in MS EXCEL   X  

registered trademark of Clariant GmbH


Overview I Home